Before contacting Alesis technical support, we recommend searching our product support Knowledge Base to see if a solution to your particular problem has already been published. Manuals Our Manuals and Quick Start Guides provide comprehensive, easy-to-understand instructions on using your device.
We are the only official ADAT repair center and have some of the only remaining original parts for ADATs in the world. If you want your ADAT restored don't hesitate to give us a call.
We think educating customers is key, so we have written a tutorial below for how to clean your ADAT transport and tape head.
Manual Cleaning Procedure Cleaning Materials For the tape path: | ||||
Lint-free cotton buds. | ||||
DO NOT USE THIS COTTON BUD TO CLEAN THE ROTARY HEAD SYSTEM. | ||||
99.9% pure Isopropyl Alcohol - available from your local pharmacy. | ||||
For the rotary head system: | ||||
Lint-free cloth. 99.9% pure Isopropyl Alcohol. or CQ video head cleaning sachet. | ||||
The sachet contains a lint-free pad already dampened with the correct cleaning solutions. | ||||
WARNING! Before proceeding, Remove The Mains Power And Other Connections To The Machine. Tape Path Description. The tape is taken from the left supply hub and travels past a stationary guide, the tension arm, P1 fixed guide, impedance roller and then P2 inclined and roller guide. From there it enters the rotating head system. On exiting from the rotating heads the tape passes around P3 inclined and roller guide across the linear head and P4 fixed guide and from there through the capstan shaft/pinch roller and onto the take-up hub. | ||||
Note that the inclined and roller guides will be located at the front of the rotary head system in the unlaced or disengaged position. Cleaning The Tape Path. All parts that come into contact with the tape should be cleaned. Refer to the drawing as an aid to identification. Adopt a logical approach following the path of the tape from the left of the transport towards the right. This will ensure nothing is missed. Use a cotton swab dipped in alcohol and adopting a sideways (horizontal), rather than an up and downward motion, clean the following components:
Make sure the white roller guide sleeves are cleaned thoroughly by rotating them. To aid identification: • Guides incorporate a channel in which the tape runs. • Posts have a constant diameter with no channel. The linear head, which resembles a conventional analog head, can be cleaned with a swab, again using side to side strokes. The capstan shaft can be cleaned with alcohol. Do not clean the pinch roller as the alcohol will cause the rubber to become hard and crack over a period of time. Unless you have specialist rubber cleaner, leave the pinch roller cleaning until its next service. Make sure any excess moisture is removed after cleaning. | ||||
Rotary Head Description. There are two main parts to this, the lower drum, which is stationary and secured to the chassis and the rotating upper drum or 'scanner' which houses the two read and two write heads. The scanner rotates in a counter-clockwise direction at high speed. The heads themselves are located at the bottom of the scanner in recesses. Their alignment is critical and should not be disturbed under any circumstances. If the condition of the head has deteriorated to the point where an ERR 7 is displayed, the use of a cleaning tape may well not be enough to clear the problem. | ||||
| ||||
IF YOU HAVE ANY DOUBTS DO NOT PROCEED. CAUTIONS: WHEN CLEANING THE ROTARY HEADS. | ||||
• Do not use any material other than lint-free cloth (CQ sachet) for cleaning the rotary head. | ||||
To clean the heads open the CQ sachet, which already contains the necessary cloth and cleaning agents. Leaving the cloth folded, place it against the drum (the easiest place is on the right-hand side of the drum) and hold it gently in place with your index finger. While applying GENTLE pressure to the drum rotate the upper half or scanner ANTI-CLOCKWISE 20 times, using the round rotor board that is secured to its top. (We repeat, it is very important that you do not move the cloth or your finger while you are rotating the scanner as this can damage or affect the alignment of the heads.) This has the effect of swiping the heads through the material and the cleaners, which dissolve out the embedded oxide and debris, depositing them onto the cloth. The result is a dark smear on the material. Continue cleaning until no more residues appear on the cloth, do not let the cloth dry out. The helical groove around the top of the lower drum should also be cleaned. As this does not spin a cotton swab moistened with alcohol will suffice. As you clean this groove, rotate the upper drum a little to keep the heads away from the swab. Do not allow the cotton swab to come into contact with the heads. Wait for two or three minutes to allow the alcohol to evaporate before inserting a tape, failure to do this will result in a tape tangle. Test the recorder while the mechanism is still exposed to be sure that the tape plays satisfactorily and that none of the indicators described in the first section of these instructions is present. Having completed the head and tape path cleaning and tested that the recorder is operating correctly, replace and secure the top plate or cover of the ADAT, return the recorder to its normal position and reconnect the mains power, audio, and control cables. |
Compiled and written by Eddie Ciletti | adat S-VHS format |
Basic Mechanical Maintenance Head Cleaning adatPinch Roller Spring Pressure Fast tips to get you out of a jam Slant Block Modification: Part One M-20 / V-8 Review & mechanical tweaks Buying a used adat | Want Help?
|